In-line UVC LED water sterilizers for water purifiers and appliances, in 2, 2.5 and 5 L/min capacities.

UV LED filter models

Overview

The JIN INTER UV LED filter disinfects water as it flows. Water passes through a quartz tube while UVC LEDs outside the tube irradiate it, damaging the DNA/RNA of microorganisms so they can no longer reproduce. No mercury and no chemicals are used. The compact, low-power module runs from a DC 24 V supply and drops into the water line of a purifier or appliance.

DC 24 VMax 100 PSIMercury-freeUp to 99.99% E. coli reduction
Download specification (PDF)

Designed to simplify your product

The module is robust, frugal and easy to power, which keeps the circuit and the parts around it as simple as possible.

Withstands water pressure and water hammer

Built to tolerate high water pressure and the water hammer caused by valve opening and closing, for up to 150,000 cycles. Maximum water pressure: 100 PSI.

Low power consumption

Only 2.5 W, 3.5 W or 5.5 W (±15%) at DC 24 V, depending on the model.

Shares your DC power supply

Runs on DC 24 V, so it can use the same DC supply as the other electrical components in your product. No separate power source is needed.

Can be powered continuously

It can be energized all the time, so no dedicated switching or timing circuit is required. Keep water inside the unit at all times and avoid dry operation.

How it works

UVC LEDs irradiating water inside the quartz tube
  1. 1

    Water in

    Microorganisms enter with the flowing water.

  2. 2

    UVC zone

    UVC LEDs outside the quartz tube irradiate the water and damage microbial DNA/RNA, preventing reproduction.

  3. 3

    Water out

    The UVC-treated water flows out of the outlet, with nothing added to it.

Mercury-free and chemical-free

Disinfects with UVC light only, without mercury or chemical disinfectants.

High UV utilization

A ray-tracing-based reflective structure directs the UVC light into the water and limits light loss.

UV shielding for fittings

Reduces UV exposure of internal fittings and plastic tubing, protecting them from UV degradation.

Compact inline design

A small cylindrical body fits into the water line, even where installation space is limited.

Water-safe construction

SUS 304 stainless steel housing and water-safe materials for water treatment applications.

Clear LED indicator

A built-in LED shows the operating status at a glance.

Three models by flow rate

All models share the same DC 24 V supply, UVC wavelength and 100 PSI pressure rating. Choose by the flow your product needs.

LU19-G1 outline drawing

Compact

LU19-G1

0.5 - 2 L/min

The smallest unit, with a Ø19.1 mm body for tight spaces in countertop and under-sink purifiers.

Power
DC 24 V, 2.5 W ±15%
UVC radiant flux
90 mW
Body
Ø19.1 x 113 mm
Water connection
1/4 inch
E. coli reduction
99.937% at 2 L/min
LE25-S2 outline drawing

Built-in flow sensor

LE25-S2

2.5 L/min

A built-in flow sensor switches the UVC LED on only when water is flowing, so no external control is needed. DC 24 V adapter included.

Power
DC 24 V, 3.5 W ±15%
UVC radiant flux
180 mW
Body
Ø25.4 x 143.2 mm
Water connection
1/4 inch quick connector
E. coli reduction
99.99% at 2.5 L/min
LU25-P3 outline drawing

Highest flow

LU25-P3

1 - 5 L/min

The highest-capacity unit, for purifiers and appliances that need up to 5 L/min.

Power
DC 24 V, 5.5 W ±15%
UVC radiant flux
270 mW
Body
Ø25.4 x 138 mm
Water connection
3/8 inch
E. coli reduction
99.994% at 5 L/min

Specification comparison

ItemLU19-G1LE25-S2LU25-P3
Rated water flow0.5 - 2 L/min2.5 L/min (min 0.5)1 - 5 L/min
Input voltageDC 24 VDC 24 V (adapter included: AC 100 - 240 V, 50/60 Hz)DC 24 V
Power consumption2.5 W ±15%3.5 W ±15%5.5 W ±15%
UVC radiant flux (VF = 24 V)90 mW180 mW270 mW
Peak wavelength270 - 280 nm270 - 280 nm270 - 280 nm
Flow sensorNoBuilt in, automatic ON/OFFNo
Operating indicatorLED indicatorMulti-function LED indicatorLED indicator
Water connection1/4 inch1/4 inch quick connector3/8 inch
Body diameterØ19.1 mmØ25.4 mmØ25.4 mm
Overall length113 mm143.2 mm138 mm
Power cable480 mm, connector to customer requirement480 mm with DC jack480 mm, connector to customer requirement
Maximum water pressure100 PSI100 PSI100 PSI
Main materialsStainless steel / quartz / aluminumStainless steel / quartz / aluminum / engineering plasticStainless steel / quartz / aluminum

Power tolerance ±15%. Peak wavelength tolerance ±3.5 nm. Operating at 275 ±5 nm, within the range of high germicidal efficiency.

Operating conditions (all models)

Water UV transmittance (UVT)

> 95% / cm

Ambient temperature

0 to +60 °C

Storage temperature

-20 to +80 °C

Operating / storage humidity

30 - 65%

Tested performance

E. coli disinfection results

ModelFlow rateInlet (CFU/mL)Outlet (CFU/mL)Reduction
LU19-G12 L/min1.9 x 10⁵12099.937%
LE25-S22.5 L/min3.1 x 10⁴< 199.99%
LU25-P35 L/min1.9 x 10⁵1199.994%

Flow-through tests with Escherichia coli in an independent laboratory. Results apply to the tested organism, model, flow rate and water conditions, and cannot be extended to all spores, protozoa or viruses.

Applications

Home and under-sink purifiers

Home and under-sink purifiers

Place it after filtration and before the drinking tap.

Dental equipment

Dental equipment

Water supplied to treatment equipment.

RVs and campervans

RVs and campervans

Water supply from the tank to the tap.

Boats and vessels

Boats and vessels

Onboard domestic water supply.

Smart farms

Smart farms

Potential use: growing-system water. Validate water quality and dose.

Food and beverage plants

Food and beverage plants

Potential use: wash and beverage water. Validate quality and flow.

Illustrative applications. Check the model flow limits, water quality and equipment requirements before installation. Other equipment such as ice makers and coffee machines can also integrate the module.

UV LED filter installed in an under-sink water purifier

Installation and operating notes

  • Install after filtration. Place the unit in the drinking water line after the filters and before the tap or dispenser.
  • Stay within the flow range. Below the minimum flow the LED is not cooled enough; above the rated flow the sterilization effect is reduced.
  • Keep water inside. Run the unit with water in it and avoid dry operation, to prevent thermal stress on the UVC LED.
  • Use clear water. Recommended for drinking water with UV transmittance (UVT) of 95% or higher. Lower UVT reduces UVC transmission.

Need specifications, samples or OEM integration?

Contact Mr. Jin-Hye Jeong (Tristan), Head Director.